Description: Network type (PROFIsafe) Camera SZ-V32NX Specifications Model SZ-V32NX *1 Type Network Type (PROFIsafe) Detection capability Minimum detectable object size Diameter 20, 30, 40, 50, 70, 150 mm 0.79", 1.18", 1.57", 1.97", 2.76", 5.91" (depends on the setting) Reflectance 1.8% min., Speed 1.6 m/s 5.25 ft/s max. *2 Detectable angle 190° ( -5° to 185° ) Response time (ON to OFF) Standard Mode Scan Cycle A 160 ms (2scans) to 1280 ms (16scans) *3 *4 Scan Cycle B 168 ms (2scans) to 1344 ms (16scans) *3 *4 Scan Cycle C 176 ms (2scans) to 1408 ms (16scans) *3 *4 High Speed Mode Scan Cycle A 80 ms (2scans) to 640 ms (16scans) *3 *4 Scan Cycle B 84 ms (2scans) to 672 ms (16scans) *3 *4 Scan Cycle C 88 ms (2scans) to 704 ms (16scans) *3 *4 Response time (OFF to ON) Response time (ON to OFF) + 150 ms Protection zone Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" 8.4 m 27.56' (Standard Mode) 5.7 m 18.70' (High Speed Mode) Minimum detectable object size: 50 mm 1.97" 5.6 m 18.37' (Standard Mode) 3.8 m 12.47' (High Speed Mode) Minimum detectable object size: 40 mm 1.57" 4.3 m 14.11' (Standard Mode) 2.9 m 9.51' (High Speed Mode) Minimum detectable object size: 30 mm 1.18" 2.9 m 9.51' (Standard Mode) 2.0 m 6.56' (High Speed Mode) Minimum detectable object size: 20 mm 0.79" 1.6 m 5.25' (Standard Mode) 1.1 m 3.61' (High Speed Mode) Warning zone Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" 26 m 85.30' (Standard Mode) 23 m 75.46' (High Speed Mode) *5 Minimum detectable object size: 50 mm 1.97" 25 m 82.02' (Standard Mode) 21 m 68.90' (High Speed Mode) *5 Minimum detectable object size: 40 mm 1.57" 24 m 78.74' (Standard Mode) 20 m 65.62’ (High Speed Mode) *5 Minimum detectable object size: 30 mm 1.18" 23 m 75.46' (Standard Mode) 18 m 59.06' (High Speed Mode) *5 Minimum detectable object size: 20 mm 0.79" 21 m 68.90' (Standard Mode) 15 m 49.21' (High Speed Mode) *5 Additional safety distance 100 mm 3.94" *6 Maximum measurement distance 60 m 196.85' *7 Maximum number of banks Max. 32 banks Multiple scanner heads Max. 3 scanner heads Camera monitoring area Monitor area: over 190° (-5° to 185°) *8 Display QVGA 2.2inch color LCD Light source Type, wavelength Infrared laser diode, 905 nm Laser Class IEC Class1 IEC/EN60825-1 FDA Class1 FDA 21CFR 1040.10, 1040.11 (Laser Notice No.50) *9 JIS Class1 JIS C6802 Control output (OSSD) Output Transistor outputs (NPN or PNP is selected in the software) Number of outputs 2 outputs Max. load current 500 mA *10 Residual voltage (during ON) Max. 2.5 V (with a cable length of 5 m 16.40') OFF-state voltage Max. 2.0 V (with a cable length of 5 m 16.40') Leakage current Max. 1 mA *11 Max. capacitive load 2.2 μF (with a load resistance of 100 Ω) Load wiring resistance Max. 2.5 Ω Inputs PNP ON-voltage: 10 to 30 V, OFF-voltage: Open or 0 to 3 V, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) NPN ON-voltage: 0 to 3 V, OFF-voltage: Open or 10 V to Power voltage, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) Non-safety related output (AUX output) Output type Transistor outputs (NPN or PNP is selected by the dedicated PC software) Number of outputs 4 outputs Max. load current Max. 50 mA Residual voltage (during ON) Max. 2.5 V (with a cable length of 5 m 16.40') Muting lamp Incandescent lamp (24 VDC, 1 to 5.5 W) or LED lamp (load current: 10 to 230 mA) can be connected Interface USB USB2.0 Ethernet Standard IEEE802.3u (100 BASE-TX) Transmission rate 100 Mbps Cable STP(Shielded Twisted Pair) cable or UTP(Unshielded Twisted Pair) cable. Category5 or higher. Connector RJ45 (IP65) 2 ports Network function PROFIsafe, PROFINET, EtherNet/IP®, UDP Cable length Power and I/O cable 30 m 98.43' or less *12 Between scanner head and display unitc 20 m 65.62' or less each *13 Ethernet cable 100 m 328.08' or less *14 Approved standards EMC EMS IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE) EMI EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA Safety IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR), IEC61508, EN61508, EN ISO13849-1, 2015 (PLd, Category3), UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8 Rating Power consumption 13.4 W (without load), 50.8 W (with load) *15 Power voltage 24 VDC ±10% (Ripple P-P 10% or less): When using a converter power supply, 24 VDC +20%/-30%: When using a battery Environmental resistance Enclosure rating IP65(IEC60529) Ambient light Incandescent lamp: 1500 lux or less *16 Operating ambient temperature -10 to +50°C 14 to 122°F (No freezing) Storage temperature -25 to +60°C -13 to +140°F (No freezing) Operating relative humidity 35% to 85% RH (No condensation) Storage relative humidity 35% to 95% RH Vibration resistance 10 to 55 Hz, 0.7 mm 0.03" compound amplitude, 20 sweeps each in X, Y, and Z directions Shock resistance 100 m/s2 328.08 ft/s2 (Approx. 10 G) 16 ms pulse, in X, Y, Z directions 1000 times each axis Material Scanner head Main unit case Magnesium Window Polycarbonate, PEI Indicator part Aluminum, PES Display unit Case Magnesium, PPS, Polycarbonate System memory Aluminum, PPE Weight Approx. 2300 g *1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005). *2 If the object to be detected moves parallel to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s 5.25 ft/s, regardless of the encoder setting. *3 The response time, protection zone, and warning zone are affected by the operation mode. *4 When using PROFIsafe, 6 ms is added to the response time. When using CIP Safety, 10ms is added to the response time. *5 20% or more reflectance is necessary for the minimum detectable object in the warning zone. *6 If there is a highly reflective background within 1.5 m 4.92' from the boundary of the protection zone, 200 mm 7.87" must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance. *7 Even when using the network data output, the maximum measured output distance is 60 m 196.85'. *8 Only applicable for the type with a camera. *9 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *10 For the SZ-V04 type and the SZ-V32 type, the load current calculation of the OSSD output and AUX output is 1.5 A or less when using one scanner head, 1.0 A or less when using two scanner heads, and 0.5 A or less when using three scanner heads. For the SZ-V32N type, the load current calculation of the OSSD output and AUX output is 1.2 A or less when using one scanner head, 0.8 A or less when using two scanner heads, and 0.3 A or less when using three scanner heads. *11 Includes when the power is OFF. *12 10 m 32.81' or less when supplying power from a battery. *13 When supplying power from a battery, the length of each connection cable should be 10 m 32.81' or less when using two scanner heads, and 5 m 16.40' or less when using three scanner heads. *14 Distance between SZ-V and Ethernet switch. *15 When using the SZ-V with series connected sensor heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation. *16 An ambient light source should not be located within ±5° of the detection plane.
Price: 2199.99 USD
Location: Saint Clair Shores, Michigan
End Time: 2024-12-09T15:37:47.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
MPN: SZV32NX
Controller Platform: Automate
Brand: KEYENCE
Type: Laser Scanner
Model: KEYENCE SZV32NX