Description: Includes: flaw detector and power cable*If it is not pictured, it is not included. For example: retail packaging, manual, or any other accessories. GE Inspection USN 60 Ultrasonic Flaw DetectorGE Inspection Technologies has optimized its USN 60 series for use in direct sunlight and operation at extreme temperatures. These new characteristics make the instruments ideally suited for outdoor use with its increased long battery operation time.The combination of the rugged USN durability, 11 hours of battery operation, fast rotary knob operation, outstanding ultrasonic performance, and the モsquare wave pulserヤ form a powerful portable ultrasonic inspection tool.Optimized outdoor use designExtreme temperature use (-20°C to +55°C /-4°F to 130°F)Easy to view in direct sunlight11 hours battery operationVibrant colorsHi-resolution color LCD display produces モAnalog Look and Performanceヤ echo dynamics.4 selectable vibrant display color schemes to match lighting conditions.Gates and gate functions are color coded for easy identification and fast adjustment.User Preferred FeaturesSimple operation with fast rotary knob adjustments; gain is always directly accessible with the left-hand rotary knob and lockable.Auto CAL makes calibration fast & easy.15 Hz to 6 kHz (spike mode) PRF and 15 Hz to 2 kHz (square mode) PRF (pulse repetition frequency)2 independent gates monitor amplitude and soundpath distance for both flaw detection and thickness measurement applications.250 KHz to 25 MHz frequency range.RF display mode enhances signal evaluation and bond inspection of dissimilar materials.4 selectable damping settings (50, 75, 150, 500 ohms) for optimum probe performance.1 mm to 28 m (0.040ヤ to 1100ヤ) range (in steel) covers thin to lengthy acoustically clean materials.dB REF key evaluates subsequent echoes gain value and amplitude against the highest echo in Gate A (reference echo) when activated.IF (Interface) Gate Option for automatic start of the display, Gate A, Gate B, and / or DAC / TCG for immersion testing applications.VGA Output Option provides an easy way to connect to a PC monitor or PC projector for viewing by large audiences or training purposes.RF Output Option outputs the raw RF waveform via a standard Lemo connector for further analysis.BEA (Backwall Echo Attenuator) Option allows independent gain control of the region under Gate B for backwall echo monitoring.Wide range of applicationsA 6 kHz pulse repetition frequency, real-time analog and TTL outputs makes the USN 60 flaw detectors series ideal for a wide range of automated systems testing applications. The exclusive SmartView feature displays even the shortest echoes for critical scanning and rotating part inspections.The quality, durability, dependability and ease of use that you have come to expect of Krautkramerメs popular USN Series of instruments remains. From rugged field inspections to high resolution thin measurements, long acoustically clean materials, and immersion systems, the USN 60 flaw detector family extends the range of applications that a portable instrument can perform. Furthermore the selectable 450V Square Wave Pulser satisfies a wide range of tough-to-penetrate applications, such as difficult to penetrate metallic applications and especially non-metals inspection like composite materials.Tools for easy weld inspectionColor Leg allows easy identification of leg and skip distances for weld inspectionGRID mode dynamically changes bands of display backgroundcolors for each leg.A-SCAN mode dynamically changes the color for each leg of the モliveヤ A-ScanWeld Rating Calculation simplifies the rating of weld indications according to AWS Specification D1.1. (Formula D = A ヨ B ヨ C).Trigonometric flaw location function with curvature correction automatically calculates depth, surface distance, and sound path to flaw along with the leg of the inspection when using angle beam probes. All TOF measurements can be displayed in mm, inches or µs.SmartView function along with variable persistence freeze modes displays the most important information (relevant shot) for a test.Real time (single shot) analog and TTL outputs handle a wide range of automated systems applications.Choose from Four Freeze Modes: ALL, Peak Std, Compare or Envelope for optimum waveform evaluation and comparison.Three Variable Persistence Modes are selectable in Freeze Envelope to visually assist flaw detection & evaluation for scanning and moving part inspections.Compare frozen reference wave-forms to live A-Scans in different colors to easily interpret test results.Documentation and recordingStore & preview a minimum of 200 user-named data sets with A-Scans for quick recall and instrument setup.UltraDOC 4 software program for bi-directional communication with a PC for easy storage of data sets with A-scan and documentation of test results.UltraMATEル software program simplifies the transfer, storage, analysis, and documentation of thickness data.Reports with A-Scans are output directly to a variety of printers.Specifications:Range USN 600.040ヤ to 1100ヤ (1 mm to 28 m) at steel velocity; range selectable in fixed steps or continuously variableMaterial VelocityContinuously adjustable from 0.0098 to 0.6299 inches/µs (250 to 16,000 m/s); 65 selectable material velocitiesDisplay Delay-20 to 3498 µs in steel (dependent on range)Probe Delay/Zero Offset0 to 999.9 µsDamping50, 75, 150, 500 ohmsGain0 to 110 dB adjustable in selectable steps 0.1, 0.5, 1.0, 2.0, 6.0, user definable, and lockedTest ModesPulse echo, dual, and thru-transmissionPulserSquare wave excitation pulsePulse Voltage (Square wave pulser mode)50 to 450 V scrollable in 10 V adjustmentsPulse Width (Square wave pulser mode)Tunable from 50 to 1000 ns in 10 ns adjustmentsPulse Energy (Spike mode)Low, HighPulse Repetition Frequency USN 60Autolow, autohigh, manually adjustable from 15 to 6000 Hz (spike mode) and 15 to 2000 Hz in square wave mode, in 5 Hz increments, external trigger (spike mode only)Bandwidth (amplifier bandpass)0.25 to 25 MHz with 10 selectable settings including broadbandGate MonitorsTwo independent flaw gates controllable over entire sweep rangeMeasurement ModesZero-to-first, multi-echo with selectable flank or peak detectionRectificationPositive halfwave, negative halfwave, fullwave, RFReject (suppression)0 to 80% linearUnitsInch, millimeter, or microsecond selectableOperating Temperature-20° to 55°C (-4° to 130°F);-25° to 70ºC (-13° to 158 º F ) storableLanguagesSelectable English, German, French, Spanish, Italian, Portuguese, Norwegian, Swedish, Finnish, Danish, Dutch, Russian, Czech, Romanian, SlovakianProbe ConnectorsBNC or LemoKeypadInternational symbolsBattery PowerLithium Ion battery pack; NiMH, NiCad or alkaline cells substitutableBattery Life11 hours on Li-Ion battery packSize11.1ヤ W x 6.75ヤ H x 6.25ヤ D (282 x 171 x 159 mm)Display640 x 480 pixels Color LCD 132.48 x 99.36 mmWeight6.6 lbs. (3.0 kg) Li-Ion battery;3.5 lbs.(1.6 kg) without batteryColor LegEasy identification of leg and skip distances for angle beam inspection in A-scan or grid background colorsWeld Rating CalculationSimplifies the rating of weld indications according to AWS specification D1.1, (formula D=A-B-C)Dust Proof/DrippingWater ProofAs per IEC 529 specification for IP54 classificationComplianceEMC/EMI: EN 55011:2007, EN 61000-6-2:2005 Ultrasound: EN 12668, ASTM E317
Price: 4500 USD
Location: La Marque, Texas
End Time: 2024-02-02T18:28:41.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Brand: GE
Unit Quantity: 1
Country/Region of Manufacture: United States