Canyon

Fluke 1587 FC 2-in-1 Insulation Multimeter, True-RMS, Up To 1000 V, Frequency

Description: Product overview: Fluke 1587 FC Insulation MultimeterKeep yourself safe. Find hidden problems faster. Put the paperwork down.Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.Add diagnostics with Fluke ConnectThe Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.Quickly find problems by saving and comparing measurements over time on a wireless device.PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems fasterMemory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over timeTemperature compensation to establish accurate baselines and relevant historical comparisonsHistorical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)Provides memory storage through Fluke Connect Measurements to eliminate the need to write down resultsIncludes live circuit detection to prevent insulation test if voltage >30 V is detectedSupports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)Incorporates VFD low-pass filter for accurate variable frequency motor drive measurementsIncludes auto-discharge of capacitive voltage for added user protectionMeasures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuityIncludes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing readingAutomatically powers off to save battery powerComes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty. Key featuresSafety first. Connect the insulation tester then keep yourself out of harm's way by monitoring your test measurements remotely.Prove your job is done right by quickly seeing and sharing insulation resistance test results wirelessly with your smartphone.Quickly find problems by saving and comparing measurements over time on a wireless device.Specifications: Fluke 1587 FC Insulation MultimeterElectrical SpecificationsAC voltage measurementRange600.0 mVResolution0.1 mVAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)6.000 VResolution0.001 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)60.00 VResolution0.01 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)600.0 VResolution0.1 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹1000 VResolution1 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹¹ 1 kHz bandwidthLow-Pass Filter Voltage Range600.0 mVResolution0.1 mVAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)6.000 VResolution0.001 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)60.00 VResolution0.01 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)600.0 VResolution0.1 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)1000 VResolution1 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)DC Voltage MeasurementRangeResolutionAccuracy ±(% of Rdg + Counts)6.000 V dc0.001 V±(0.09% + 2)60.00 V dc0.01 V±(0.09% + 2)600.0 V dc0.1 V±(0.09% + 2)1000 V dc1 V±(0.09% + 2)Input impedance 10 MΩ (nominal), <100 pFNormal mode rejection ratio >60 dB @ 50 Hz or 60 HzCommon mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)Accuracies apply to ± 100% of rangeDC Millivolts MeasurementRangeResolutionAccuracy ±(% of Rdg + Counts)600.0 mVdc0.1 mV±(0.1% + 1)DC and AC Current MeasurementAC 45 Hz to 1000 HzRange400 mAResolution0.1 mAAccuracy ±(% of Rdg+Counts)±(1.5% + 2)¹Burden voltage (Typical)2 mV/mARange60 mA Resolution0.01 mA Accuracy ±(% of Rdg+Counts)±(1.5% + 2)¹Burden voltage (Typical)2 mV/mADCRange400 mAResolution0.1 mAAccuracy ±(% of Rdg+Counts)±(0.2% + 2)Burden voltage (Typical)2 mV/mARange60 mAResolution0.01 mAAccuracy ±(% of Rdg+Counts)±(0.2% + 2)Burden voltage (Typical)2 mV/mAOverload600 mA for 2 minutes maximumFuse protection for mA input0.44 mA, 1000 V, IR 10 kAAC conversionInputs are ac-coupled and calibrated to the rms value of sine wave inputConversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.¹ 1 kHz bandwidthOhms MeasurementRangeResolutionAccuracy +(% of Rdg+Counts)¹600.0 Ω0.1 Ω±(0.9% + 2)6.000 kΩ0.001 kΩ±(0.9% + 2)60.00 kΩ0.01 kΩ±(0.9% + 2)600.0 kΩ0.1 KΩ±(0.9% + 2)6.000 MΩ0.001 MΩ±(0.9% + 2)50.0 MΩ ²0.01 MΩ±(1.5% + 3)Overload protection 1000 V rms or dcOpen circuit test voltage <8.0 V dcShort circuit current <1.1 mA¹ Accuracies apply from 0% to 100% of range² Up to 80% relative humidityDiode TestDiode test indicationDisplay voltage drop: 0.6 V at1.0 mA nominal test current:Accuracy±(2% + 3)Continuity TestContinuity indicationContinuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 ΩOpen circuit voltage<8.0 VShort circuit current1.0 mA typicalOverload protection1000 V rmsResponse time>1 m secFrequency MeasurementRangeResolutionAccuracy ±(% of Rdg+Counts)99.99 Hz 0.01 Hz ±(0.1% + 1)999.9 Hz 0.1 Hz ±(0.1% + 1)9.999 kHz 0.001 kHz ±(0.1% + 1)99.99 kHz 0.01 kHz ±(0.1% + 1)Frequency Counter Sensitivity600.0 mV ac V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 mV V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz150.0 mV DC Trigger Levels¹ to 20 kHz²NA6.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 1.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz1.5 V DC Trigger Levels¹ to 20 kHz²-400.0 mV and 2.5 V60.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 10.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz36.0 V DC Trigger Levels¹ to 20 kHz²1.2 V and 4.0 V600.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz-DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V1000.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 300.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz-DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy² Usable to 100 kHz with full scale inputCapacitanceRange Resolution Accuracy ±(% of Rdg+Counts)1000 nF 1 nF±(1.2% + 2)10.00 μF 0.01 μF±(1.2% + 2)100.0 μF 0.1 μF±(1.2% ±90 counts)9999 μF 1 μF±(1.2% ±90 counts)Temperature MeasurementRange Resolution Accuracy ±(% of Rdg+Counts)¹-40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts)-40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts)¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrumentInsulation SpecificationsMeasurement range0.01 MΩ to 2 GΩTest voltages50, 100, 250, 500, 1000 VTest voltage accuracy+20%, -0%Short-circuit test current1 mA nominalAuto dischargeDischarge time <0.5 second for C = 1 μF or lessLive circuit detectionInhibit test if terminal voltage > 30 V prior to initialization of testMaximum capacitive loadOperable with up to 1 μF loadOutput Voltage50 V (0% to +20%)Display range0.01 to 6.00 MΩResolution0.01 MΩTest current1 mA @ 50 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)Display range6.0 to 50.0 MΩResolution0.1 MΩTest current1 mA @ 50 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)100 V (0% to +20%)Display range0.01 to 6.00 MΩResolution0.01 MΩTest current1 mA @ 100 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)Display range6.0 to 60.0 MΩResolution0.1 MΩTest current1 mA @ 100 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)Display range60 to 100 MΩ Resolution1 MΩTest current1 mA @ 100 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)250 V (0% to +20%)Display range0.1 to 60.0 MΩ Resolution0.1 MΩTest current1 mA @ 250 kΩ Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)Display range60 to 250 MΩ Resolution1 MΩTest current1 mA @ 250 kΩ Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)500 V (0% to +20%)Display range0.1 to 60.0 MΩResolution0.1 MΩTest current1 mA @ 500 kΩ Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)Display range60 to 500 MΩResolution1 MΩTest current1 mA @ 500 kΩ Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)1000 V (0% to +20%)Display range0.1 to 60.0 MΩ Resolution0.1 MΩTest current1 mA @ 1 MΩResistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)Display range60 to 600 MΩ Resolution1 MΩTest current1 mA @ 1 MΩResistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)Display range0.6 to 2.0 GΩ Resolution100 MΩ Test current1 mA @ 1 MΩResistance accuracy ±(% of Rdg + Counts)±(10% + 3 counts)General SpecificationsMaximum voltage applied to any terminal and common1000 VStorage temperature-40 °C to 60 °C (-40 °F to 140 °F)Operating temperature-20 °C to 55 °C (-4 °F to 131 °F)Temperature coefficient0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)Relative humidityNoncondensing0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)VibrationRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrumentRadio frequency communication2.4 GHz ISM BandRadio frequency certificationFCC: T68-FBLE, IC: 6627A-FBLEElectromagnetic Compatibility InternationalIEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class AGroup 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.Enclosure protectionIEC 60529: IP40 (non-operating)SafetyIEC 61010-1Pollution Degree 2IEC 61010-2-033CAT IV 600 V / CAT III 1000 VBatteries Four AA batteries (IEC LR6)Battery lifeMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.Size (H x W x L)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)Weight550 g (1.2 lb)AltitudeOperating2000 mStorage12,000 mOver-range capability110% of range except for capacitance which is 100%Frequency overload protection<107 V HzFuse protection for mA input0.44A, 1000 V, IR 10 kA

Price: 819.95 USD

Location: Brooklyn, New York

End Time: 2024-08-25T03:31:53.000Z

Shipping Cost: N/A USD

Product Images

Fluke 1587 FC 2-in-1 Insulation Multimeter, True-RMS, Up To 1000 V, FrequencyFluke 1587 FC 2-in-1 Insulation Multimeter, True-RMS, Up To 1000 V, FrequencyFluke 1587 FC 2-in-1 Insulation Multimeter, True-RMS, Up To 1000 V, FrequencyFluke 1587 FC 2-in-1 Insulation Multimeter, True-RMS, Up To 1000 V, Frequency

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Seller

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money Back

Measurement Category: CAT III

Brand: Fluke

DC Voltage Range: 1000

Form Factor: Handheld

Test/Measurement Functions: AC Current, DC Voltage, Capacitance, Continuity Test, DC Current, AC Voltage

Maximum Input Voltage: 1000V

AC Voltage Range: 1000

MPN: 1587FC

Features: Auto Power Off, Auto-Ranging, Battery Door Access

Display: Digital

Recommended

New Fluke 2AC 90-1000V VoltAlert Non-Contact Voltage Tester
New Fluke 2AC 90-1000V VoltAlert Non-Contact Voltage Tester

$25.99

View Details
Fluke 1587 + AC/DC CLAMP i410 USED FAST SHIPPING
Fluke 1587 + AC/DC CLAMP i410 USED FAST SHIPPING

$350.00

View Details
S Clean Used Fluke 902FC HVAC Digital Handheld Clamp Meter w/Fluke Leads & Bag +
S Clean Used Fluke 902FC HVAC Digital Handheld Clamp Meter w/Fluke Leads & Bag +

$209.00

View Details
Fluke 302+ plus AC400A Clamp Tester AC/DC Volt Amp Multimeter Average 400A NEW
Fluke 302+ plus AC400A Clamp Tester AC/DC Volt Amp Multimeter Average 400A NEW

$69.90

View Details
Fluke 83 83-III 83-V 85 85-III 87 87-III 87-V 88 88-V 787 Input Terminal Jacks
Fluke 83 83-III 83-V 85 85-III 87 87-III 87-V 88 88-V 787 Input Terminal Jacks

$32.95

View Details
Fluke 1AC-C2II VoltAlert Non-Contact Voltage Detector Pen Tester W/sound
Fluke 1AC-C2II VoltAlert Non-Contact Voltage Detector Pen Tester W/sound

$21.79

View Details
FLUKE 2AC-C2 VoltAlert Non-Contact Voltage Pen AC200-1000v Detector Tester Meter
FLUKE 2AC-C2 VoltAlert Non-Contact Voltage Pen AC200-1000v Detector Tester Meter

$24.80

View Details
Fluke 17B+ 600 V CAT III Digital Multimeter AC/DC Current Voltage Temperature
Fluke 17B+ 600 V CAT III Digital Multimeter AC/DC Current Voltage Temperature

$124.87

View Details
2Sets Multimeter Test Leads for Fluke Meter Electrical Alligator Clip Probes 20A
2Sets Multimeter Test Leads for Fluke Meter Electrical Alligator Clip Probes 20A

$8.99

View Details
Fluke 302 + Handheld Digital Clamp Meter Tester AC / DC Volt Amp Multimeter NEW
Fluke 302 + Handheld Digital Clamp Meter Tester AC / DC Volt Amp Multimeter NEW

$74.98

View Details