Canyon

30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul

Description: Product Name: 30A 12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Module Package inlcuded: 1 PCS30A Multifunction AC/DC motor Reversiblecontroller Description: 1 Working voltage: DC 12V 2 Working current: (Normal Mode) standby current 21mA, working current 110mA; (Energy-Saving mode) Standby current 7mA, working current 75mA. 3 There are three input control ports: forward control(FWD), reverse control(REV), and stop control(STOP). 4 Two input trigger modes, Low-Pulse trigger mode, Low-Level trigger mode 5 Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes. 6 Cycle times: no cycle, 2-99 cycles, always cycle. 7 Three indicators: forward indicator(F LED), reverse indicator(R LED), stop indicator(S LED). 8 6 functional modes. 9 Relay load current: 30A 250VAC/30VDC 10 Size: 97.5*56*24mm 11 Weight: about 87 grams This is a 30A multi-function DC/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings. Port: VIN : Power supply positive DC 12V GND : Power supply negative FWD : Forward input control (partial Function-Mode is invalid) REV : Reverse input control (partial Function-Mode is invalid) STOP : Stop input control (partial Function-Mode is invalid) M+ : Motor positive M- : Motor negative P+ : Positive motor power supply P- : Negative motor power supply Wiring: The working power supply is 6.5-25VDC. The motor is a DC 1-110V DC motor or AC 85-265V AC motor. How to use: Q&A: Q1: Why is the digital tube not lit after power-on? A1: This is because the Energy-Saving mode is set, please press and hold the OK button for 5 seconds to exit the energy saving mode. Q2: Why does the motor not work after the motor is connected to the M+/M- port? A2: The working power and motor power of the board are independent. You need to supply power to the motor. The power port is P+/P- port. It is recommended to use two separate power supplies for the working power supply and the motor power supply. Q3: Why is the parameter setting invalid? A3: After setting the parameters, be sure to re-power,Parameter settings can be saved permanently. Trigger mode: 1 low pulse trigger (falling edge trigger) 2 low level trigger (rising edge trigger) Timer: T1: Forward timer T2: Reverse timer T3: Stop timer Time unit : 0.1 second, 1 second, 1 minute Relay action: Motor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing. Motor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing.. Motor stop : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing. Factory settings: Press the ++ and -- buttons simultaneously for 5 seconds. Energy-saving mode: Press and hold the OK button for 5 seconds to enter the Energy-saving mode. Press and hold the OK button again for 5 seconds to exit the Energy-saving mode. Energy saving mode just turns off the digital tube and LED indicator, and other functions are normal. Function mode: F-01 After power-on, the motor is forward T1 time; then the motor stops T3 time; then the motor reverse T2 time; so it is repeated Nx times. When the STOP port is triggered, the motor stops working immediately. (FWD, REV port is invalid) F-02 This function is a F-01 variant. F-01 is run directly after power-on, but F-02 needs to trigger FWD or REV port to run. F-11(Trigger reversible 1) Trigger the FWD port, the motor is forward T1 time, and automatically stops (in order to protect the motor, during the delay period, trigger the REV port to stop T3 time and then reverse T2 time, trigger FWD port to re-time T1). Trigger the REV port, the motor is reverse T2 time, and automatically stops (in order to protect the motor, during the delay period, the FWD port is triggered to stop the T3 time and then the T1 time is forward, and the REV port is re-timed T2). When the STOP port is triggered, the motor stops immediately, regardless of whether the motor is forward or reverse. F-12(Trigger reversible 2) Trigger the FWD port, the motor is forward T1 time and stops automatically (during the delay period, except for triggering STOP port, the other ports are invalid). Trigger the REV port, the motor is reverses T2 time, and automatically stops (during the delay period, except for triggering STOP port, the other ports are invalid). When the STOP port is trigger, the motor stops immediately, regardless of whether the motor is forward or reverse. F-21 When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops. When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops. In this mode, the FWD and REV ports cannot be connected low level at the same time, and the STOP port is invalid. F-22 When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops. When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops. In this mode, the FWD and REV ports cannot be connected low level at the same time, triggering the STOP port, the motor stops immediately. Parameter setting: There are three menus: Work Menu, Function Menu, Parameter Menu. Note: When entering the Function Menu or Parameter Menu, the module still works normally (countdown and the trigger is running normally). The set parameters are valid only after being powered on again. 1 Power on to enter the running state (Work Menu). If the current function is F-01, then the motor direct run and the digital tube displays the countdown. F-01 is displayed after the operation is completed. If the current function is other functions, such as F-11. Then the digital tube displays F-11. After the trigger, the digital tube displays the countdown. After the operation is completed, F-11 is displayed. Description: The forward countdown F LED indicator flashes, the reverse countdown R LED indicator flashes, and the S LED indicator flashes when stopped. 2 In the running state(Work Menu), short press the SET button to enter the Function Menu (Above table). 3 Press the SET button under Function Menu to enter the Parameter Menu.(Above table) In the Parameter Menu, short press the SET button to select the parameters of 1-9, and set the parameters through the ++ button and the -- button. Short press the OK button to save the current settings and return to the previous menu (Function Menu) Description: 1 Timer T1 T2 T3 time unit is 0.1 sec / sec / min, so the timing range of T1 T2 T3 is 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes 2 The number of cycles is the number of repeated actions (Nx =0 means always loop, Nx =1 means no loop). So you can set the number of loops: 1-99 times or forever loops. 3 F-21, F-22 function, Nx=1 parameter can not be changed

Price: 14.89 USD

Location: Guangzhou

End Time: 2024-07-19T07:19:06.000Z

Shipping Cost: 2.99 USD

Product Images

30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul30A12V DC/AC Motor Forward & Reverse Controller 0.1-999.9S Delay Relay Modul

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money Back

Brand: eletechsup

Type: Relay

MPN: IO52B02

Recommended

With Acrylic Shell 7.83HZ 0.01H-100KH Schumann Resonance Pulse Sine Wave Generat
With Acrylic Shell 7.83HZ 0.01H-100KH Schumann Resonance Pulse Sine Wave Generat

$17.98

View Details
DC 12 24V MEGA2560 Pro Expanding Board Current Voltage ADC Collection NPN PNP
DC 12 24V MEGA2560 Pro Expanding Board Current Voltage ADC Collection NPN PNP

$55.13

View Details
1A NiMH Rechargeable Battery Multipurpose Charger 1.5V 3V 4.5V CC/CV Charging
1A NiMH Rechargeable Battery Multipurpose Charger 1.5V 3V 4.5V CC/CV Charging

$2.97

View Details
2001 FANUC ROBODRILL ELETECHSUP 1 CHANNEL BI STABLE RELAY DC 5-24V VCC GND T
2001 FANUC ROBODRILL ELETECHSUP 1 CHANNEL BI STABLE RELAY DC 5-24V VCC GND T

$59.99

View Details
USB boost-buck step up-down DC DC converter Voltage regulator 1.2V-6V to 5V
USB boost-buck step up-down DC DC converter Voltage regulator 1.2V-6V to 5V

$2.29

View Details
2 PCS DC 5V-12V Motor Reversible Controller Time adjustable Delay Relay Switch
2 PCS DC 5V-12V Motor Reversible Controller Time adjustable Delay Relay Switch

$6.00

View Details
DC 12V  433M Wireless RS485 IO Point-to-Point Master-Slave RF Transceiver
DC 12V 433M Wireless RS485 IO Point-to-Point Master-Slave RF Transceiver

$22.89

View Details
20W DC 3.7-30V PWM ON/OFF Control LED Driver Module 330/500/660/910MA Constant
20W DC 3.7-30V PWM ON/OFF Control LED Driver Module 330/500/660/910MA Constant

$1.99

View Details
DC 6-24V 22W Adjustable Constant Current Step-Down High Brightness LED Driver
DC 6-24V 22W Adjustable Constant Current Step-Down High Brightness LED Driver

$1.99

View Details
DC 12V 24V 8AI-8DI-8DO Expansion Board RS485 Analog Collection Wifi Relay Switch
DC 12V 24V 8AI-8DI-8DO Expansion Board RS485 Analog Collection Wifi Relay Switch

$19.99

View Details